Mindray BeneHeart D2 D3 Defibrillator Power Supply Board

PANSW PRODUCT CATALOGUE

Mindray BeneHeart D2 D3 Defibrillator Power Supply Board

Internal power supply board for compatible Mindray BeneHeart D2 and D3 defibrillator-monitors. The assembly includes the transformer, filtering components, fuses, capacitors, inductors, and heatsink shown in the photograph.

Ask about this product

Send your equipment model, required quantity and destination country. We will help confirm compatibility and availability.

WhatsApp: +86 136 8886 0726
sales@panswmed.com

Product information

Specifications

Brand Mindray
Compatible Model D2 D3
Product Type Maintenance Part
Category Machine maintenance parts
Product Type Internal power supply board / power PCB
Compatible Brand Mindray
Product Family BeneHeart
Compatible Models D2 / D3
Visible Marking 2105-20-40298C
Visible Component Marking C-0651-20-76900 VB
Included Item One power supply board as pictured
Cables Included Not shown
Defibrillator Included No
Installation Qualified service personnel only
Condition Please confirm before ordering

Product Overview

This power supply PCB is used in compatible Mindray BeneHeart D2 and D3 defibrillator-monitors as part of the internal power conversion and distribution system. It is to replace an original board affected by power-up failure, unstable output, damaged connectors, heat damage, failed capacitors, or other board-level faults after diagnosis by a qualified technician. The supplied configuration is limited to the board and attached components visible in the photograph. The defibrillator, battery, high-voltage therapy board, main board, cables, and other assemblies are not included unless specifically confirmed.

Application and Ordering Notes

Before ordering, compare the original board’s complete part number, PCB revision, dimensions, mounting holes, connector locations, transformer and heatsink layout, fuse arrangement, and component markings with the photograph. Mindray BeneHeart D2 and D3 hardware revisions may use different power boards. This high-voltage medical-device component should be installed and tested only by qualified service personnel following the manufacturer’s procedures.

Quality and Compatibility Notice

Compatibility information is provided for reference. Please verify the exact connector, model, and clinical application before ordering.

Need help matching a component?

Send the model, part number and a clear photo.

Ask PanSW