Pre-Owned Dräger Fabius GS Tiro Plus 8604607 GPFM115-28-107 Power Supply Module

Pre-owned Condor GPFM115-28-107 AC/DC power supply module for selected Dräger Fabius anesthesia machines. It accepts 100–240V AC input and provides 28V DC output. Please confirm the machine model, serial number, OEM part number, connector arrangement, and module label with PanSW before ordering.

Brand
Dräger
Compatible Model
Dräger Fabius GS Tiro Plus 8604607 GPFM115-28-107
Product Type
Maintenance Part
Category
Machine maintenance parts
Note
Specification Details
Note
Product type AC/DC power supply module
Note
Condition Pre-owned; removed from equipment
Note
Power-supply manufacturer Condor D.C. Power Supplies / SL Industries
Note
Power-supply model GPFM115-28-107
Note
Dräger OEM reference 8604607
Note
Reported replacement reference 4117060
Note
Input voltage 100–240V AC
Note
Input current 2.3A
Note
Input frequency 50/60Hz
Note
Output with forced-air cooling +28V DC, 4.1A
Note
Output with calm-air cooling +28V DC, 1.78A
Note
Housing Ventilated metal enclosure
Note
Label markings CE LVD, UL Recognized and TÜV markings shown

Product Overview

This pre-owned Condor GPFM115-28-107 power supply module was removed from medical equipment and is intended for the repair and maintenance of compatible Dräger Fabius anesthesia machines. The module converts a universal 100–240V AC input to a regulated 28V DC output. The label specifies an output of 28V DC at 4.1A with forced-air cooling or 28V DC at 1.78A under calm-air cooling. Because different Fabius models and production revisions may use different power supplies, wiring, connectors, or mounting arrangements, compatibility must be confirmed before ordering. Please send PanSW clear photographs of the existing module label, connectors, mounting points, machine model, and serial number. This product should be installed and tested only by a qualified biomedical engineer or medical-equipment technician.

Application and Ordering Notes

The Dräger OEM reference and reported fitments are supported by a medical-parts cross-reference for OEM number 8604607. It lists Fabius GS, Tiro, OS, MRI and Tiro M; Fabius Plus compatibility should therefore be individually confirmed.

Quality and Compatibility Notice

Compatibility information is provided for reference. Please verify the exact connector, model, and clinical application before ordering.

Compatibility confirmation: For Pre-Owned Dräger Fabius GS Tiro Plus 8604607 GPFM115-28-107 Power Supply Module, please confirm connector shape, patient-end type, cable length, machine model, and OEM part number if available.