Pre-Owned Mindray PM-7000 Patient Monitor Mainboard, Power Board, LCD, ECG, NIBP and Repair Parts
Pre-owned repair parts for the Mindray PM-7000 multiparameter patient monitor. Available components include mainboards, power boards, LCD assemblies, ECG and SpO₂ boards, NIBP modules, keypad boards and housing parts. All components are supplied separately.
Product Overview
PanSW supplies dismantled components for repairing and maintaining Mindray PM-7000 patient monitors. The PM-7000 was manufactured in different hardware and parameter configurations. Available parts can include electronic boards, parameter modules, display assemblies, control components and enclosure parts. Exact compatibility must be confirmed through the complete part number, battery system, parameter configuration and connector layout. Documented Part References Component Part number or reference Mainboard 9210-30-30150 Earlier CPU board, 4 MB flash CS9K-30-16531 Power board for lead-acid battery 7001-30-67438 Earlier lead-acid power board 7000-30-24468 Power board for lithium battery 7001-30-67439 Earlier lithium-battery power board 7000-30-24469 Display assembly 7001-30-67456 10.4-inch TFT LCD 0000-10-11021 Earlier 10.4-inch TFT LCD 0010-10-12136 ECG board 812A-30-08557 / 812A-30-08569 Earlier ECG board DA8K-30-14504 NIBP PCB assembly 630D-30-09111 NIBP pump 630D-30-09121 SpO₂ board 9006-30-33900 Earlier SpO₂ board 9005-30-08530 Nellcor SpO₂ module 7000-30-24511 Masimo SpO₂ module 0010-10-12274 Button/keypad board 7001-30-67441 Alarm-light board 9200-30-10701 Display encoder mounting board 6200-30-09774 Front-bezel assembly 7001-30-67413 Front bezel 7000-20-24354-51 Rear-housing assembly 7001-30-67450 Rear housing 7000-21-24435 Battery door 7000-20-24361 Carrying handle 7000-20-24359 Power-socket assembly 7001-30-67454 These references come from documented PM-7000 service parts lists. Different revisions must be compared before ordering
Application and Ordering Notes
Please provide:
Monitor serial number
Complete part number and revision
Photographs of both sides of the original component
Lead-acid or lithium-battery configuration
LCD manufacturer and model
Installed SpO₂ technology: Mindray, Nellcor or Masimo
Connector arrangement
Description of the monitor fault
A PM-7000 part with a different reference number should not be treated as interchangeable without comparison.
Installation Notice
Installation should be performed by a qualified biomedical technician. After replacement, verify the display, keypad, ECG, SpO₂, NIBP, temperature, alarms, recorder, battery charging and all installed parameters. NIBP leakage and calibration tests and complete electrical-safety testing should be performed before clinical use.
Quality and Compatibility Notice
Compatibility information is provided for reference. Please verify the exact connector, model, and clinical application before ordering.