Compatible Battery for Creative Medical PC9000 Patient Monitor – 12V 2300mAh

Compatible replacement battery pack for the Creative Medical PC9000 (PC-9000) multiparameter patient monitor. Rated at 12V and 2300mAh, with a nominal energy of 27.6Wh. The battery is supplied with lead wires, but the end connector or terminal is not included.

Brand
Creative
Compatible Model
PC9000
Product Type
Battery Pack
Category
Medical batteries
Note
Item Specification
Note
Product Type Compatible patient monitor battery
Note
Compatible Brand Creative Medical / Creative
Note
Compatible Model PC9000 / PC-9000
Note
Voltage 12V
Note
Capacity 2300mAh / 2.3Ah
Note
Nominal Energy 27.6Wh
Note
Length 178 ± 1 mm
Note
Width 35 ± 1 mm
Note
Height 61 ± 1 mm
Note
Lead Wires Included
Note
Connector / Terminal Not included
Note
Battery Chemistry Please confirm according to the original battery
Note
Condition New
Note
Brand PanSW or compatible

Product Overview

This compatible battery is designed for use with the Creative Medical PC9000 multiparameter patient monitor. It provides a replacement power source for monitors with an aged, damaged, or low-capacity internal battery. The battery has a nominal voltage of 12V and a rated capacity of 2300mAh, equivalent to 27.6Wh. Its elongated housing measures approximately 178 × 35 × 61 mm, allowing it to fit the corresponding battery compartment. This version is supplied with lead wires only. The connector or terminal at the end of the wires is not included. The original terminal may need to be transferred and connected by a qualified technician. Voltage, dimensions, wire polarity, and terminal configuration must be verified before installation.

Application and Ordering Notes

Before ordering or installation, please verify:

Original battery voltage and capacity

Battery dimensions

Number and color of wires

Positive and negative wire polarity

Original connector and terminal configuration

The original terminal may need to be reused or installed onto the new battery wires. Installation should be completed by a qualified biomedical or electronic service technician. Incorrect polarity or wiring may damage the battery or monitor.

Quality and Compatibility Notice

Compatibility information is provided for reference. Please verify the exact connector, model, and clinical application before ordering.

Compatibility confirmation: For Compatible Battery for Creative Medical PC9000 Patient Monitor – 12V 2300mAh, please confirm connector shape, patient-end type, cable length, machine model, and OEM part number if available.