Replacement Battery for Philips HeartStart FR3 AED – 12V 4.7Ah Li-MnO₂ – 989803150161

A 12V 4.7Ah non-rechargeable lithium manganese dioxide battery compatible with the Philips HeartStart FR3 AED. It replaces battery part number 989803150161 and provides approximately 56.4Wh of nominal energy

Replacement Battery for Philips HeartStart FR3 AED – 12V 4.7Ah Li-MnO₂ – 989803150161
Brand
Philips
Compatible Model
HeartStart FR3 AED
Product Type
Battery Pack
Category
Medical batteries
Note
Non-rechargeable Li-MnO₂ primary battery
Note
Approximately 56.4Wh nominal energy
Note
Designed as a compatible replacement for FR3 AED batteries
Note
Long storage shelf life when handled correctly
Note
PanSW compatibility-confirmation support before ordering

Product Overview

This compatible replacement battery is designed for the Philips HeartStart FR3 automated external defibrillator. It uses lithium manganese dioxide primary-cell technology and is supplied as a single-use, non-rechargeable battery. The battery has a nominal voltage of 12V and a rated capacity of 4.70Ah, providing approximately 56.4Wh of nominal energy. Published FR3 battery information indicates a storage shelf life of up to five years when unused and stored correctly. Reference performance is typically up to 300 shocks or approximately 12 hours of monitoring, depending on the battery’s age, storage conditions, temperature, AED self-tests and actual operating conditions. Reference information Specifications Battery type: Lithium manganese dioxide primary battery Chemistry: Li-MnO₂ Rechargeable: No Nominal voltage: 12V Rated capacity: 4.70Ah Nominal energy: Approximately 56.4Wh Dimensions: 100 × 68 × 47mm Approximate weight: 285g Color: Black Reference shelf life: Up to five years when unused and properly stored Reference performance: Typically up to 300 shocks or 12 hours of monitoring

Application and Ordering Notes

This is a primary battery and must not be recharged. Confirm the AED model, original battery number, connector and physical configuration before ordering.

This battery is intended for the HeartStart FR3 and should not be assumed compatible with the HeartStart FRx, OnSite/HS1, FR2/FR2+ or other AED models.

Quality and Compatibility Notice

Compatibility information is provided for reference. Please verify the exact connector, model, and clinical application before ordering.

Compatibility confirmation: For Replacement Battery for Philips HeartStart FR3 AED – 12V 4.7Ah Li-MnO₂ – 989803150161, please confirm connector shape, patient-end type, cable length, machine model, and OEM part number if available.